Introduction to Acid-Base Titration
An acid-base titration is a quantitative analytical technique used to determine the concentration of an acid or base solution. It involves the gradual addition of a solution of known concentration (the titrant) to a measured volume of another solution of unknown concentration (the analyte) until the reaction between them is complete. The point at which the reaction is complete is called the endpoint, which is detected by a suitable indicator that changes colour.
The titration relies on precise measurement of volumes and careful observation of colour changes to calculate the unknown concentration accurately. The main apparatus used are the burette, volumetric pipette, and indicator.
- Titrant: solution of known concentration, usually in the burette.
- Analyte: solution of unknown concentration, measured by volumetric pipette.
- Indicator: chemical that changes colour at the endpoint of the reaction.
Role and Use of the Burette
The burette is a long, graduated glass tube with a tap at the bottom, designed to deliver variable volumes of liquid accurately, typically to the nearest 0.05 cm³. It is used to add the titrant solution to the analyte gradually and precisely.
Before starting, the burette is rinsed with the titrant solution to avoid dilution. It is then filled with the titrant, ensuring no air bubbles are present in the nozzle. The initial volume is recorded to two decimal places.
During titration, the tap is opened to allow the titrant to flow dropwise near the endpoint to avoid overshooting. The final volume is recorded, and the volume of titrant used is calculated by subtracting the initial reading from the final reading.
- Graduated scale allows volume measurement to ±0.05 cm³.
- Tap controls flow rate for precise delivery.
- Used to add titrant until the endpoint is reached.
Role and Use of the Volumetric Pipette
The volumetric pipette is a piece of glassware designed to measure a fixed, accurate volume of liquid, commonly 25.0 cm³, with an uncertainty of ±0.03 cm³. It is used to transfer a known volume of the analyte solution into a conical flask for titration.
Before use, the pipette is rinsed with the analyte solution to prevent contamination. The liquid is drawn up to the calibration mark using a pipette filler, ensuring the bottom of the meniscus aligns exactly with the mark at eye level.
The analyte is then delivered into the conical flask by touching the tip to the inside of the flask and allowing the liquid to drain freely without blowing out the last drop, ensuring accurate volume delivery.
- Measures fixed volume accurately (e.g., 25.0 cm³).
- Rinsed with analyte to avoid dilution.
- Delivers analyte to conical flask for titration.
Role and Selection of an Appropriate Indicator
An indicator is a chemical that changes colour at (or very close to) the equivalence point of the titration, signalling that the acid and base have reacted completely. The choice of indicator depends on the strength of the acid and base involved, as different indicators change colour at different pH ranges.
For example, phenolphthalein changes from colourless to pink around pH 8.2–10, suitable for titrations involving strong base and weak acid. Methyl orange changes from red to yellow around pH 3.1–4.4, suitable for strong acid and weak base titrations.
The indicator is added in a few drops to the analyte solution before titration begins. The endpoint is identified by the first permanent colour change that persists when titrant is added dropwise.
- Indicator signals endpoint by colour change.
- Choice depends on acid-base strength and pH at equivalence point.
- Added to analyte before titration starts.
Step-by-Step Titration Method
1. Rinse the burette with the titrant solution and fill it, recording the initial volume.
2. Rinse the volumetric pipette with the analyte solution, then use it to transfer a measured volume (e.g., 25.0 cm³) of analyte into a clean conical flask.
3. Add 2–3 drops of a suitable indicator to the analyte in the conical flask and swirl gently to mix.
- 4. Place the conical flask on a white tile to observe colour changes clearly.
- 5. Slowly open the burette tap to add titrant to the analyte, swirling the flask continuously.
- 6. Near the endpoint, add titrant dropwise until the indicator changes colour permanently.
- 7. Record the final burette reading and calculate the volume of titrant used.
- 8. Repeat the titration until at least two concordant titres (within 0.10 cm³) are obtained for accuracy.
Calculations and Worked Example
The concentration of the unknown solution is calculated using the titration data and the balanced chemical equation. The general formula is:
\[ \text{Concentration of analyte (mol/dm}^3) = \frac{\text{moles of titrant}}{\text{volume of analyte (dm}^3)} \]
Moles of titrant are calculated from its concentration and volume used: \( \text{moles} = \text{concentration} \times \text{volume} \). Volumes must be converted from cm³ to dm³ by dividing by 1000.
- Balanced equation used to find mole ratio between titrant and analyte.
- Calculate moles of titrant from volume and concentration.
- Calculate moles of analyte using mole ratio.
- Calculate concentration of analyte from moles and volume.
At-a-glance summary
Comparison table
| Step | Chemical Detail | Evidence | Exam Use |
|---|---|---|---|
| Using burette | Delivers titrant of known concentration | Volume readings to 0.05 cm³ | Marks for correct apparatus and precision |
| Using volumetric pipette | Measures fixed volume of analyte accurately | Volume fixed at e.g. 25.0 cm³ | Marks for accuracy and correct volume |
| Adding indicator | Indicator changes colour at endpoint | Colour change observed | Marks for correct indicator choice and endpoint detection |
| Titration process | Titrant added until neutralisation | Colour change signals endpoint | Marks for correct procedure and endpoint identification |
| Calculation | Use balanced equation and volumes | Correct formula and substitution | Marks for correct calculation and units |
Active recall
Quick check
1. What is the purpose of the burette in an acid-base titration?
To deliver the titrant solution of known concentration accurately and measure the volume added precisely.
2. Why is a volumetric pipette used to measure the analyte?
Because it measures a fixed, accurate volume of the analyte solution, ensuring precise calculation of concentration.
3. How does an indicator help in a titration?
It changes colour at the endpoint, signalling that the acid and base have completely reacted.
4. What must you do before filling the burette with titrant?
Rinse the burette with the titrant solution to avoid dilution or contamination.
5. How do you calculate the concentration of the analyte from titration data?
Calculate moles of titrant from its concentration and volume used, use the balanced equation to find moles of analyte, then divide moles of analyte by its volume in dm³ to find concentration.